RD-220™ is a freely flowing multi-component blend prepared for combating lost circulation in drilling fluids. RD- 220™ is effective in a range of fracture plugging and is used as a maintenance treatment and higher addition rates when significant mud loss occurs. RD-220™ can be used for all invert fluids, including synthetics and in fresh and saltwater mud.
PROPERTIES, TYPICAL
Appearance |
Gray Powder and Fibers |
Density (lb/ft3) |
54 Avg (44 Uncompacted /64 Compacted ) |
Flash Point |
< 200° F (COC) |
APPLICATION
- 2-10 ppb As preventative maintenance lost circulation material in drilling fluids
- 15 – 30 ppb as slug treatment
ADVANTAGES
- Can reduce the initiation of fracture formation specially in depleted sands
- No adverse effect on rheological or filtration control properties
- Does not plug drilling equipment
- Not classified as hazardous material
TREATMENT RATE
- Pre-treat with 2 – 10 ppb in the system as you drill
- Use 2 to 4 ppb for maintenance
- For partial losses send slugs of 10 to 20 ppb
- For complete losses prepare a 20 to 30 ppb sludge pill
**NOTE**
Always pilot test before adding the product so the allow amount of product would be added.
PACKAGING
- 25 Lbs Bags (40 Bags / Pallet)
PRESSURE PLUGGING TEST RESULTS
The following tables are the results of the RD-220™ PPT Evaluation:
Oil Base Mud |
275.8 ml Diesel |
6 grams Emulsifier |
3.9 grams Lime |
3.9 grams Organophilic Clay |
60.2 ml Calcium Chloride Brine 10.8 ppg |
691 grams Barite |
15 grams LCM Additive (RD-220) |
55 μm (60 μm old air porosity measurement) Ceramic Disks |
PPT, Spurt |
PPT Fluid Loss, ml |
Oil Base Mud, 16 ppg diesel based |
|
41 |
15 lb/bbl RD-220 |
14 |
27 |
120 μm (90 μm old air porosity measurement) Ceramic Disks |
PPT, Spurt |
PPT Fluid Loss, ml |
Oil Base Mud |
14 |
36 |
15 lb/bbl RD-220 |
12.5 |
28.5 |
The information contained on this page is correct to the best of our knowledge, but is intended only as a source of information. The recommendations or suggestions herein are made without guarantee or representation as to results, and we suggest that you evaluate the recommendation contained on this page in your own laboratory prior to use. Our responsibility for claims arising from breach of warranty, negligence or otherwise is limited to the purchase price of the material.